Specifications

2.2 Paper Feeding System
2.2.1 Size Sensing Cassettes
Table 2–1 shows the size sensing switch code. The three size sensing switches
are set by keys that are attached to the right side wall of each cassette.
The keys on the fixed cassette are molded into the body of the cassette. The
keys on the universal cassette are set by the user.
The size sensing information is compared to the user-requested size. If a
mismatch occurs, an operator load tray message appears.
Table 2–1 Size Sensing Switches
Paper
Size Sensing Switches
Size SW603 SW604 SW605
Legal On On Off
Letter On Off On
Executive Off On On
B5 Off On Off
A4 Off Off On
No cassette Off Off Off