Specifications
B.2 Connecting PC or IBM Compatible Systems
B.2 Connecting PC or IBM Compatible Systems
The MS–DOS and Windows PC operating system use the parallel and serial
ports to communicate with the printer. The parallel port is the system’s
default. The serial port is used when the parallel port is occupied.
• Use the parallel port if the printer is less than 3 meters (10 feet) from your
computer.
The parallel port supports IEEE 1284 bidirectional and Centronics
unidirectional communications.
• The DEClaser 5100 printer serial port supports both the EIA-232 and
EIA-422 communication protocols. EIA-323 is universally accepted while
EIA-422 is available on most systems.
– Choose EIA-232 for distances up to 15 meters (50 feet) and baud rates
up to 19200. Use lower speeds for longer distances.
– Choose EIA-422 for high baud rates and long distances.
• The default serial communications settings are:
Baud rate 9600 bits per second
Parity None
Flow control XON/XOFF (2-way)
Stop bits 1
Mode EIA-232
XON/XOFF For AT compatible ports
DTR/DSR For PC compatible ports
B–2 General Information