Specifications
9.26 Guide, HVPSA Contact Plate
9.26 Guide, HVPSA Contact Plate
Note: The procedure to remove and replace the HVPSA contact plate is
complicated, difficult, and might require several attempts to achieve. The
procedure consists of the following sub-steps:
1. Remove all preliminary FRUs
2. Remove the crossmember
3. Remove the transport guide plate
4. Remove the pivot pin that actuates the scanner safety shutter when the
EP-ED cartridge is installed
5. Remove the left EP-ED guide plate
6. Remove the HVPSA contact plate
Caution: The plastic pieces of the parts that required handling can be easily
damaged. This might result in deteriorated image quality or intermittent
unaccountable faults. If you find a damaged clip or any other damage, replace
the part do not attempt to fix it.
1. Remove the following preliminary parts:
FRU As shown in section:
a. Paper cassette –
b. Transfer roller 9.31
c. Front door
guide plate
9.22
d. Control panel assembly 9.2
e. Left-side cover 9.18
f. Right-side cover 9.19
g. Top cover 9.20
h. Fusing Unit 9.25
i. High-voltage power
supply assembly
9.4
9–60 Removing and Replacing FRUs