Technical data

4.4 Blank, Silent, and Inoperative Control Panel FIP
4.4 Blank, Silent, and Inoperative Control Panel FIP
Description: When the printer is turned on, the control panel is either blank,
hung, or producing confusing indications. This is caused by a problem in the
ac line power, the LVPSA, DC control board, or the control panel.
Troubleshooting: If the display, indicators, or keys fail to perform, try
powering the printer off, then on. Perform the following procedure to fix this
problem:
1. Inspect the video cooling fan and the TEST LED on the rear of the printer.
The fan is powered by the 24 Vdc supply through the 2-pin P52 connector
on the LVPSA. The TEST led is powered by the 5 Vdc power supply. If the
fan is exhausting air and the TEST LED is lit, skip to step 3.
2. Inspect the following power line items:
The line cord for cuts, fraying, or damage. Do not repair a damaged
line cord, replace it.
Both ends of the line cord are correctly attached.
AC power source is alive and within specification listed in Table B–6.
3. Inspect the following plugs and connectors that are shown in Figure 4–2:
All LVPSA connectors
All DC control board connectors, particularly P30 and P31
Control panel connectors
4–6 Start FIP and Nonerror Code FIPs