Technical data
4.4 Blank, Silent, and Inoperative Control Panel FIP
4.4 Blank, Silent, and Inoperative Control Panel FIP
Description: When the printer is turned on, the control panel is either blank,
hung, or producing confusing indications. This is caused by a problem in the
ac line power, the LVPSA, DC control board, or the control panel.
Troubleshooting: If the display, indicators, or keys fail to perform, try
powering the printer off, then on. Perform the following procedure to fix this
problem:
1. Inspect the video cooling fan and the TEST LED on the rear of the printer.
The fan is powered by the 24 Vdc supply through the 2-pin P52 connector
on the LVPSA. The TEST led is powered by the 5 Vdc power supply. If the
fan is exhausting air and the TEST LED is lit, skip to step 3.
2. Inspect the following power line items:
• The line cord for cuts, fraying, or damage. Do not repair a damaged
line cord, replace it.
• Both ends of the line cord are correctly attached.
• AC power source is alive and within specification listed in Table B–6.
3. Inspect the following plugs and connectors that are shown in Figure 4–2:
• All LVPSA connectors
• All DC control board connectors, particularly P30 and P31
• Control panel connectors
4–6 Start FIP and Nonerror Code FIPs