Technical data

4.1 Start FIP
4.1 Start FIP
Figure 4–1 shows the Start FIP flow and each step is described in Table 4–1.
Table 4–1 Start FIP
Step Results and action
1. Check the temperature
and humidity
The printer is designed to operate in a shirtsleeve
temperature range specifically 10–32° C (50–90° F). An
overheating printer causes image defects. Make sure
the back, side, and all the air vents are not blocked
with desk clutter.
2. Toner spills Clean up any spilled toner and find and fix the source
of the spill.
3. Prepare the printing for
testing
Power down, remove the font cartridges, and select
DEC PPL3 protocol, as shown in Section 3.4.
4. Power up the printer If the printer fails to power up correctly, do one of the
following:
If the display is blank, scrambled, or hung up and
the indicators are inoperative or not correct, go to
Section 4.4, Blank, Silent, and Inoperative Control
Panel FIP.
If the printer makes questionable noises, go to
Section 4.2, Noises.
If an error message is displayed go to Table 5–1,
Error Code Master Lookup Table.
5. Press
Online/Pause
The Online indicator goes out and PAUSED appears on
the display. The printer is off line.
6. Press
Test
to enter the
Test menu.
The message CONFIG SHEET appears.
7. Press
to print a copy
of the CONFIG SHEET,
as shown in Section 2.6
If the configuration sheet prints and the image quality
is good, go to the TCC procedure in Section C.1.
If an error message is displayed, go to Table 5–1,
Error Code Master Lookup Table.
If the configuration sheet is blank, black, or the
image is defective, go to Section 7.1, Image Defect
Lookup, to identify and fix the image defect.
(continued on next page)
4–2 Start FIP and Nonerror Code FIPs