Technical data
3.1 1701 Special Function and Test Codes
Table 3–2 (Cont.) 1701 Test Codes
Test
Code
Display or
Prompt Definition
0925 SENSING Toner empty sensor.
1000 data This feature is not usable in a field environment. Displays
fuser temperature in an unknown code.
1001 data Fuser thermistor continuity.
1010 (Listen) The fuser fan must accelerate to a higher speed.
1100 COMPLETE The exit motor in forward direction at high speed.
1101 COMPLETE The exit motor in forward direction at low speed.
1102 COMPLETE The exit motor in reverse direction.
1103 COMPLETE Offset motor test. Use the following procedure:
1. Select and run test.
2. Open exit door.
3. Insert sheet of paper under exit sensor.
4. Close exit door.
5. Exit and offset motor will run and eject sheet of paper.
Note: When you see the SENSING prompt, you must manually actuate the sensor under test.
You may need the interlock cheating tool for covers open operation. The tool is part of the
miscellaneous parts kit, shown in Table 8–1.