Technical data

3.1 1701 Special Function and Test Codes
Table 3–1 (Cont.) 1701 Special Function Codes
Code Definition of Function Display Panel/Comment
0282.08
1
Show toner status T:ID=10:90/05/10
SUMiDA-B Sim-B1
0282.60 Set laser power Do not change this
adjustment. If any value
other than $0A is displayed,
reset the $0A factory default
value.
0282.70 Set fuser temperature Do not change this
adjustment. If any value
other then $03 is displayed,
reset the $03 factory default
value.
0282.80 Set scanner auto on time See Section 10.1 for the
adjustment procedure
0282.90 Set fuser power saver time See Section 10.2 for the
adjustment procedure.
0304
0308
DC control board ROM
DC control board ROM test
V03.01 S:$00
PASS–FAIL
0900 Pages left on print drum 0019627
0901 Pages left on developer cartridge 0049740
0902 Pages left on toner supply cartridge 0005740
1
This direct code can be entered from the 0000 prompt, without entering the 1701 code.
3–4 Service Menus and Tests