Technical data

E.1 DEC PPL3 Submenu
E.1.1 TRAY SELECTION
This feature selects the following paper input feeder. In addition to selecting a
singular tray, a sequence of trays can be selected to indicate the tray fail-over
order.
Feature Values Description
TRAY TRAY 1
1
Feeds paper from the upper paper cassette.
TRAY 2 Feeds paper from the lower paper cassette.
TRAY 3
2
Feeds paper from the optional LCIT.
TRAY 1-2 When TRAY 1 is empty, feed paper from TRAY 2.
TRAY 1-3
2
When TRAY 1 is empty, feed paper from TRAY 3.
TRAY 2-3
2
When TRAY 2 is empty, feed paper from TRAY 3.
TRAY 1-2-3
2
When TRAY 1 is empty, feed paper from TRAY 2.
When TRAY 2 is empty, feed paper from TRAY 3.
MANUAL Selects the manual feed mode of operation.
MMF
3
Feeds paper from the optional MMF.
1
Factory default setting.
2
Displayed only if the LCIT option is installed.
3
Displayed only if the MMF option is installed.
E.1.2 DUPLEX
The following values are available from the DUPLEX submenu of the DEC
PPL3 menu. A thorough explanation of the duplex values is beyond the scope
of this guide. See the DEClaser 3200 Printer Operator’s Guide and the Digital
ANSI-Compliant Printing Protocol Level 3 Programming Reference Manual for
more information.
Feature Values Description
DUPLEX SIMPLEX
NORMAL
1
Selects true simplex normal operation; binding is on
the long edge.
DUPLEX
NORMAL
Selects true duplex normal operation; binding is on
the long edge.
SIMPLEX
TUMBLED
Selects true simplex tumbled operation; binding is
on the short edge.
1
Factory default setting.
Resident Protocols E–3