Technical data
10
Adjustments and Cleaning Procedures
This chapter covers the DEClaser 3200 adjustments and cleaning procedures.
10.1 Setting Auto Scan
Scanner auto time is the time that the scanner remains on while a job is
processing in the video control board. Use the following procedure to enter,
change, and exit the Auto Scan menu:
1. Press and hold
Defaults
and
>
while powering up the printer.
2. When you see four zeros (0000), press the menu mode keys to set the 1701
code and press once to enter it, as shown in Table 3–1.
3. Press the menu mode keys to set the 0282 code and press to enter it.
4. Press the menu mode keys to set the 0282.80 code.
5. Press to enter the code. The current setting, or default, is displayed.
The following example demonstrates Auto Scan menu:
$39 : 570 sec
$ A dollar sign acts as a prompt.
39 The two digit hexadecimal set code. The higher order digit (3) changes the
the time by ±160 second increments. The lower order digit (9) changes the
time by ±10 second increments.
: A colon separates the set code from the offset display.
570
sec
The time display is the time in seconds, approximately 9.5 minutes. The
recommended setting is $01: 20
6. Press the menu mode keys to change the set code and alter the Auto Scan
time display.
7. Press to enter the Auto Scan time.
8. Press
>
and
Defaults
to exit Auto Scan set menu. The four zeros (0000)
will reappear.
Adjustments and Cleaning Procedures 10–1