Technical data
Table 10–2 LN15 Configuration Settings
Setting Value Where Set Documentation
PERSONALITY PS Printer console
CONFIG menu
LN15 User Manual
NPAP MODE OFF Printer console
PARALLEL menu
LN15 User Manual
PORT 1 BITRONICS ENABLED Ethernet card
management
RapidPrint 600 Print
Server Installation
Guide
10.9 DIGITAL Laser Printer LN17+ps
The DIGITAL Laser Printer LN17+ps is an upgrade to the DIGITAL LN17ps
printer. References in the DCPS documentation to the DIGITAL LN17ps
printer also apply to the DIGITAL Laser Printer LN17+ps.
10.9.1 Job Remains in Starting State
If you use a raw TCP/IP or LAT-connected LN17ps printer with DCPS, the
associated DCPS print job may remain in a Starting state.
You must either set the Ethernet port to use the PostScript language and
disable automatic language sensing, or define a DCPS$queuename_NO_SYNC
system logical for the associated queue.
• If all the print jobs that the printer receives from its Ethernet port come
from DCPS, including PCL jobs that use the printer’s native PCL 5e
interpreter, do the following:
Set the printer’s Ethernet port System Language to PostScript and turn off
Language Sensing. You change these settings from the interface menu on
the printer console, as described in the LN17ps User Guide.
• If any of the print jobs that the printer receives from its Ethernet port do
not contain PostScript data (for example, they contain PCL or ASCII data)
and DCPS is not the source of such data, do the following:
Enable Language Sensing on the the printer’s Ethernet port. Define a
DCPS$queuename_NO_SYNC system logical for the associated queue as
described in Section 3.4.3.
10–8 Printer-Specific Information