Interval Timer Tests
Figure 4–1 Loopback Descriptions for Interval Timer Test 3 and 4
ML013463
Configuration for Interval Timer test 3
To make a loopback for test 3 connect pin C11 to C14. With a second jumper,
connect C12 to C13.
row C
B
A
14 13 12 11
Configuration for Interval Timer test 4 (MASTER/SLAVE Alpha VME)
For test 4, the MASTER signals must be the input for the second Alpha VME
module. Connect pins C11 and C14 of the MASTER to C14 of the SLAVE.
With a second jumper, connect C12 and C13 of the MASTER to C13 of the
SLAVE.
(VMEbus P2 Connector)
row C
B
A
14 13
(VMEbus P2 Connector, SLAVE)
C
B
A
14 13 12 11
(VMEbus P2 Connector, MASTER)
Diagnostics 4–15