Specifications

App - 29
Appendix 2 Conversion Specifications for GP-PRO/PB III Series
Appendix 2.9 LS area
3 Checking the converted data
• Check the
conversion result.
Conversion result • When the conversion is completed, the conversion result is
displayed. The conversion result data is stored in the conversion
destination folder.
• For error information and others, refer to the section specified as
reference in this manual.
5.4 Checking Conversion
Result
Converted data • Check that the following files are output with the conversion.
• *.TXT: Conversion result
• *.g1: Converted screen data (Binary format)
• *.g1d: Converted screen data (Binary format)
(*: File name of original data)
-
• When the data is not
correctly converted
When the data is
correctly
converted by
correcting the
original data
before conversion
• When the GP size of the original data is 0, the data may not be
converted correctly. This can be improved by saving each screen
again with the GP-PRO/PB series and converting the data.
• Grouped tags and parts may not be converted correctly. Cancel
the grouping with the GP-PRO/PB series and convert the data
again.
-
When the data
requires to be
corrected
manually after
conversion
• When the screen background color after conversion differs from
that before conversion (The color after conversion is the paint
color of GT Designer2.)
This is because the paint mark of a closed figure on the screen is
out of the figure on the screen after conversion. This is also
because the figure is not completely closed. Find the point that
requires correction with the converted data, and correct the
position of the paint mark or correct the figure so that the figure is
completely closed.
(When the correction point is for a switch figure, register the
switch figure in the library, and then make corrections.)
-
• Others Precautions • The initial screen number of the initial screen settings is not
converted.
The conversion is available by using the script function or a
ladder program.
(This manual describes the setting example.)
Appendix 2.1 Conversion
specifications of project
data
• The device assigned to the control address of a text table is
converted into the language switching device when only
[GOT1000] is set for [Output Type].
Conversion
specifications
• Alarm data
• Text table
• Screen type
• Basic comment and comment group
• GP type Appendix 2.2 GP type
• PLC type Appendix 2.3 PLC type
• Screen information Appendix 2.4 Screen
information
• Graphic data Appendix 2.5 Graphic data
• Tag information Appendix 2.6 Tag
information
• Parts information Appendix 2.7 Parts
information
• D-Script Appendix 2.8 D-Script
• LS area Appendix 2.9 LS area
• Overall tags Tag conversion availability
list (Contact your local
Mitsubishi representative.)
Procedure
Points to be checked
(Including precautions and tips for conversion)
Reference