Specifications
1
OUTLINE
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
GT CONVERTER2
SCREEN LAYOUT
5
GT CONVERTER2
OPERATION METHODSAPPENDICES
Appendix 2 Conversion Specifications for GP-PRO/PB III Series
Appendix 2.1 Conversion specifications of project data
App - 4
Appendix 2 Conversion Specifications for GP-PRO/
PB III Series
This section explains conversion specifications of the GP-PRO/PB III series.
(The conversion specifications in this appendix indicate only those of the main items.)
(1) Precautions for data conversion
GT Converter2 will not be liable for the damage caused by data conversion, from
the existing data to GOT1000 series or GOT-A900 series.
Before downloading converted project data to the GOT, be sure to check GT
Designer2 setup and make corrections if necessary.
Note that any function that is not supported by the conversion destination GOT
will not be converted.
(2) Converting a file with a name in other than English (Japanese, Chinese or other
language)
The file cannot be converted when the file name is in other than English.
Change the file name to English before conversion.
(3) Converting a file including character strings in other than English (Japanese,
Chinese or other language)
The character strings cannot be converted correctly when the conversion source
file includes character strings in other than English.
Change the character strings to English with the drawing software before
conversion.
The same conversion specifications of GT Converter2 are applied to all versions of the GP-PRO/PB III
series.
Therefore, all the GP-PRO/PB III series versions can be used.
Even the items described convertible in this Appendix may not be convertible depending on project setup.
If conversion failed in some items, descriptions of the error items are given in conversion log.
Section 5.4 Checking Conversion Result
Appendix 2.1 Conversion specifications of project data
1 Restrictions of project data
The following describes the restrictions related to project data conversion.
(a) Setting items related to a memory card are inconvertible.
(b) When the device has been assigned to the control address of a text table, only the device in
GOT1000 format is converted into a Language Switch device.
The device in GOT-A900 format is inconvertible.
(c) When "The target base screen of the L tag settings is converted to parts" is selected on Option,
the graphic data on the base screen read by the L-tag is converted into parts.
Section 5.3.2 Conversion option settings
(d) Mark screens are inconvertible. Since parts of GT Designer2 function as same as Mark
screen, recreate the Mark screens with GT Designer2 parts after conversion.