Specifications
5 - 6
5.3 Conversion
5.3.2 Conversion option settings
5.3.2 Conversion option settings
Set conversion methods on the conversion settings screen.
1 Make the following settings.
: Applicable, : Not applicable
(When converting the project data for GOT800 series.)
(When converting the project data for GP-PRO/PB series.)
Item Description
Source file format
ProPB/
Win
ProPB/
DOS
GOT800
Change text background
color
When checked, the rectangle filled with a background color is placed
behind the character string.
Applicable only when "GOT-A900" format is selected for “Output Type”.
For GOT1000 series, a background color can be converted regardless of
this setting item.
Convert Base Screen into
Parts.
When checked, the base screen in the conversion source file is converted
into a base screen and parts.
In this case, only the graphic data placed on the base screen of the conver-
sion source file are converted into parts.
When not checked, it is converted into the base screen only.
The target base screen of
the L tag settings is
converted to parts.
When converting the L tag into parts display, set the part type. When
checked, it is set to parts.
When not checked, it is set to the base screen.
This option setting is available when "Convert Base Screen into Parts."
shown above is check-marked.
Convert the password.
When checked, the password for conversion source file is converted into
the password for [Data Transmission/Utility].
Primary Log Alarm
Select the log alarm to be converted.
Log alarm that is not selected is not converted.
Output type
When converting it into "GOT1000 Binary Files (*.G1)", select GOT1000
type.
When converting it into "GT Designer Files (A9GOTP.GOT)", select GOT-
A900 type.
When you mark this checkbox,
this square shape is inserted
underneath.
Alarm buzzer