Transmitter Overheat Indicator (Temp Dot)
Each transmitter has a temperature overheat indicator (temp dot) on the front end cap. The
temp dot has an outer yellow ring with a
1
/
8
in. white dot in the center.
Transmitter Temp Dot
If the temp dot changes to silver or gray, the transmitter has been exposed to heat but not in
excess of specifications. If the temp dot is black, the transmitter has been exposed to
excessive temperatures and can no longer be used. The DCI warranty does not cover any
transmitter that has been overheated (black dot) or had its temp dot removed.
Avoid transmitter overheating by practicing proper drilling techniques. Abrasive soils, clogged
jets, inadequate mud flow, and improperly mixed mud all contribute significantly to the over-
heating of a transmitter.
The Falcon transmitter stores the maximum temperature, which you
can view using the Transmitter Info function. Note that the external
temp dot can reach 220° F and turn black before the internal
temperature reaches 220° F.
Transmitter Information
Page 31
Changing Frequency Bands
With the receiver at the Locate screen, hold toggle right to open the
Band Selection menu, where you can switch between the Up and Down
frequency bands and enable or disable fluid pressure monitoring.
Band Selection Menu
Page 31
On the transmitter, use the following procedures to switch between the
two optimized frequency bands, such as when performing an
interference check, or an AGR test in both bands with the transmitter in
the drill head prior to drilling.
Installing Batteries /
Power On
Page 65
Above Ground (Pre-Bore) Tilt Method
Do not roll the transmitter more than two clock positions (CP) during this procedure.
1. Place the transmitter on an approximately level surface (0±10°) for at least five seconds
with the receiver at the Locate screen and transmitter data being displayed.
2. Tilt the transmitter up at approximately 65° (over 100%, or nearly vertical).
3. Hold the transmitter steady for 1018 seconds.
4. Return the transmitter to level within 10 seconds.
Normal
temp dot
Black temp dot
voids warranty