User's Manual
DIGITAL CONTROL INCORPORATED
22 DigiTrak Falcon
™
F5
Operator’s Manual
2. From the Main menu, select HAG. The HAG menu displays with Enable HAG highlighted
and the current or 24 in. default HAG setting shown in the description line at the bottom
of the screen. If the HAG had previously been enabled, Disable HAG would be
highlighted.
HAG Menu
3. If the HAG value shown at the bottom of the screen is acceptable, select Enable HAG.
Skip the next step.
4. To change the HAG value shown at the bottom of the screen, select
Set HAG and enter a new value. After you press the execute button on
that screen, the receiver beeps four times and returns to the Main
menu with the new HAG setting enabled.
Using the Keypad
Page 12
Depth readings (holding the trigger) must now be taken with the receiver held at this height.
As noted above, to prevent incorrect readings, HAG must be manually turned on each time
the Falcon F5 receiver is powered on.
I use HAG all the time; can I set it to turn on automatically?
No. In the name of safety, HAG must be turned on manually for each use. However, the
feature does remember the last height value used.
Set HAG
Disable HAG
Enable HAG