User's Manual
Table Of Contents
- Operator’s Manual
- Digital
- Control
- Incorporated
- DCI Headquarters 19625 62nd Ave. S., Suite B-103 Kent, Washington 98032 USA Tel 425 251 0559 / 800 288 3610 Fax 253 395 2800 E-mail DCI@digital-control.com www.digitrak.com
- Important Notice
- Safety Precautions and Warnings
- Safety Precautions and Warnings (Continued)
- _
- Introduction
- _
- Receiver
- Power On
- Toggle and Trigger Switches
- Speaker and Audible Tones
- Adjusting Screen Contrast
- Main Menu
- Locate Menu
- Set US Menu
- Low Fre/High Fre Menu
- Configure Menu
- Changing the Telemetry Channel
- 1-Point Calibration
- 2-Point Calibration (In-ground Calibration)
- Changing the Grade Mode
- Changing the Depth Measurement Mode
- Cold Screen / Normal Screen
- Tele Option A/B
- Locator DL / No Locator DL (Enabling and Disabling DataLog Menus)
- Set Roll / Unset Roll (Enabling and Disabling Roll Offset Function)
- Remote Display
- _
- Transmitter
- _
- Battery Charger
- _
- Locating
- _
- The Target Steering® Function
- _
- Cable System
- Cable System Components
- Non-DCI Supplies Required for Operating the Cable System
- Connecting Power Supply to Power Source and Cable Transmitter
- Grounding the Cable Transmitter
- Cable Transmitter On/Off
- Calibrating the Cable Transmitter
- Enabling the Roll Offset Function on the Remote Display
- Locating Using the Cable System
- Viewing Transmitter Depth or Predicted Depth
- Viewing Status of Cable System Power Source
- Target Steering Function Using the Cable System
- Troubleshooting
- _
- Appendix
- Depth Increase in Inches (Centimeters) per 6-foot (1.8 meter) Rod
- Depth Increase in Inches (Centimeters) per 10-foot (3-meter) Rod
- Depth Increase in Inches (Centimeters) per 15-foot (4.6-meter) Rod
- Percent of Grade to Degree Conversions (0.1% Pitch Transmitters or Sensitive Pitch)
- Degree to Percent of Grade Conversions (0.1% Pitch Transmitters)
- Calculating Depth Based on Distance Between FLP and RLP
- LIMITED WARRANTY
Receiver
Locate Menu
Accessing Locate Mode
• From the main menu screen, push the toggle down once or toggle left to select Locate, then click the
trigger. You will see the locate mode screen.
• From any screen other than the main menu, push down twice on the toggle to advance to the Locate
menu, then click the trigger to enter the locate mode. You will see the locate mode screen.
SH
7.5
%
CH:B1
411
75
°
F
Locate Mode Screen
Displaying Depth (From the Locate Screen)
1. From the locate mode, hold in the trigger—the depth or predicted depth of the transmitter will be
displayed. You will also see the ultrasonic height setting and the battery status of the receiver and the
transmitter.
2. Release the trigger and you will be returned to the locate mode screen.
NOTE: You will only see depth (or predicted depth) while at the FLP, RLP, or on the LL (see the
Locating section for information on the FLP, RLP, and LL).
Exiting Locate Mode and Returning to Main Menu
From the locate mode, push the toggle down once to return to the main menu.
14 DigiTrak
®
Eclipse
®
Operator’s Manual