User's Manual
Table Of Contents
- Safety Precautions and Warnings
- Dear Customer:
- Introduction
- Receiver
- Transmitter
- Remote Display
- Battery Charger
- Locating Instructions
- Appendix A: System Specifications and Maintenance Requirements
- Appendix B: Projected Depth Versus Actual Depth and the Fore/Aft Offset
- Appendix C: Calculating Depth Based on Distance Between FLP and RLP
- LIMITED WARRANTY
DIGITAL CONTROL INCORPORATED
Appendix A:
System Specifications and
Maintenance Requirements
The power requirements, environmental requirements, and equipment maintenance requirements for the
DigiTrak LT2 Locating System are listed below.
Power Requirements
Device Voltage Current
DigiTrak LT2 Receiver 14.4 V DC (nominal) 0.25 A DC
DigiTrak LT2 Remote Display 14.4 V DC (nominal) 0.25 A DC
DigiTrak LT2 Battery Charger
12–28 V DC
100–240 V AC, 50/60 Hz
2.0 A DC
Environmental Requirements
Altitude < 16,404 ft (< 5000 m)
Temperature -4°F to 140°F (-20°C to 60°C)
Relative Humidity < 90%
Equipment Maintenance
Turn off all equipment when not in use.
Store the LT2 equipment in cases, away from heat, cold, and moisture. Perform tests to confirm
proper operations.
Clean the LT2 receiver, remote, and battery charger by using a soft moist cloth and detergent.
Do not use chemicals to clean the transmitter.
Clean the LCD screens on the receiver and remote display using a soft cloth without chemicals.
Use plain water if necessary.
Inspect the LT2 equipment daily and contact DCI if you see any damage or problems. Do not dis-
assemble or attempt to repair the equipment.
Do not ship the LT2 locating equipment with batteries inside. Always remove the batteries from
the equipment before shipping.
DigiT
rak
®
LT2™ Operator’s Manual 59