User's Manual

Table Of Contents
DIGITAL CONTROL INCORPORATED
Battery Charger
Rechargeable
Battery Pack
Une
xposed Terminal
DO NOT EXPOSE
DC Power
Cord
Control Panel
AC Adapte
r
AC
Power
Cord
Negative
Terminal
Positive
Terminal
Battery Charger
General Description
The DCI battery charger unit, which includes AC and DC power cords and an AC adapter, is provided
with the LT2 system, along with three rechargeable DCI battery packs. The battery packs are used to
power the LT2 receiver and the remote display.
The battery charger can operate from AC (100–240 V) or DC (12–28 V) power sources. The battery
charger has specific cords for AC or DC power sources, as shown in the photo above. The AC power
cord is also specific to your global geographic area of operation.
A fully charged battery pack measures between 16.5 V and 17.1 V and will power an LT2 receiver for
approximately 8 hours or an LT2 remote display for approximately 12 hours before recharging is required.
A battery is considered discharged at 14.4 V.
Only two terminals are exposed on a battery pack (as shown in above photo). If the third terminal
becomes exposed or the insulating material over the battery shows signs of damage, the battery pack
must be replaced through an authorized dealer.
Charging or using damaged or non-DCI battery packs may damage the charger, the receiver, or the
remote display, and will void the warranty.
DigiT
rak
®
LT2™ Operator’s Manual 39