The main display screen indicates when the receiver is over the transmitter or the locate line (LL) by
showing arrows above and below the depth value, as shown below. The receiver display will show the
line in the box.
Depth Reading When Receiver Is Above Transmitter or LL
In this display, the downward arrow is pointing to the transmitter to indicate that the reading is the actual
depth of the transmitter or LL. If there is not an arrow pointing down from the depth reading, then the
depth value shown indicates the slant distance (see Locating Instructions section).
NOTE: If you see four dashed lines ( — — — — ) where the distance/depth number should display,
then the receiver is too close to the transmitter and it is getting saturated with signal (see
“Height Above Ground” menu discussion in the Receiver section).
By holding in the on/off button for 2 seconds or more, the transmitter temperature will display in place of
the pitch information and the telemetry channel will display in place of the height-above-ground setting, as
shown below.
On/Off Button Held In
Arrow pointing to tool
head indicates the line
is in the box and the
receiver is above the
transmitter or the LL.
Telemetry Channel Replaces
Height-Above-Ground Setting
Transmitter Temperature
Replaces Pitch Reading