User's Manual

Table Of Contents
Receiver
Vermeer
®
DigiTrak
®
L
T
Operator’s Manual 21
7. You should see a depth reading that matches this measured distance, which in our example would be
6 ft (1.83 m).
F*F
8. Repeat the above two steps in at least two more locations.
DEPTH UNITS
This display menu allows you to set the LT system to display values (depth and temperature) in either
English units (FT
IN
or “in” and °F) or metric units (M
CM
and °C).
1. Click the trigger to advance to the depth units menu. The display will indicate the current setting.
2. Hold the trigger in through the countdown sequence from 3 to 0.
Depth Units Display Menu
3. When the counter reaches 0, you will see the unit setting change and a checkmark appear at the bot-
tom of the display.
4. Release the trigger to return to the standard locating screen.
NOTE: The depth units can be set on both the receiver and the remote display.
It is recommended
that the receiver and the remote display be set to the same depth units.
*Depth tolerance is 5%; thus, at a distance of 6 ft (1.83 m), the error tolerance is 3.6 in. (9 cm).