User's Manual
Table Of Contents
Receiver
Vermeer
®
DigiTrak
®
L
T
™
Operator’s Manual 19
3. When the counter reaches 0, the light bulb will either light up as the backlight comes on or it will
become unlit and the backlight will turn off.
4. Release the trigger to return to the standard locating mode screen.
NOTE: The backlight automatically comes on for a few seconds at startup, and then it defaults to
the off setting, even if you have reset it previously.
1-PT CALIBRATION
This display menu allows you to calibrate the receiver using the 1-point calibration procedure. The 1-point
calibration procedure is performed with the transmitter in the housing, as described later in this section.
DCI recommends that you verify that the receiver’s depth readings are accurate at several locations using
a tape measure before you drill. Calibration is necessary prior to first-time use and whenever a different
transmitter, receiver, or housing is going to be used.
Do not calibrate if:
¾ You are within 10 ft (3 m) of metal structures, such as steel pipe, chain-link fence, metal siding,
construction equipment, or automobiles.
¾ The receiver is over rebar or underground utilities.
¾ The receiver is in the vicinity of excessive electrical interference.
¾ The transmitter is not installed in the housing.
¾ The transmitter is not turned on.
NOTE: Calibration is necessary prior to first-time use and whenever a different transmitter, re-
ceiver, or housing is going to be used.
The 1-point calibration menu display appears as follows:
1-Point Calibration Screen