Perform Level Check
This check confirms that the internal sensors that measure the inclination of the receiver are working
correctly. An inaccurate sensor would cause erroneous depth and location readings.
Place the receiver on generally level ground and click Continue . The ground does not have to be
perfectly level.
Level Test Screen 1
Rotate the receiver 180 degrees so it faces the opposite direction, as illustrated by the icon on the screen,
and click Continue again.
Level Test Screen 2
The receiver beeps four times, flashes a confirmation message, and returns to the Main menu.
If the level check fails, the receiver beeps twice and displays an error screen. Click Retry and repeat the
test as described above. If the check fails again, contact DCI Customer Service.
Perform System Self-Test
This self-test performs a system check on internal components. Ensure no transmitters are powered on
during this test. The receiver beeps four times after a successful test and displays the receiver Startup
Screen (shown on page 11). Click to return to the Diagnostics menu.