User's Manual
Table Of Contents
- Safety Precautions and Warnings
- Dear Customer:
- Introduction
- Receiver
- Transmitter
- Remote Display
- Battery Charger
- Locating
- The Target Steering Function
- Appendix A: System Specifications and Maintenance Requirements
- Appendix B: Projected Depth Versus Actual Depth and the Fore/Aft Offset
- Appendix C: Calculating Depth Based on Distance Between FLP and RLP
- LIMITED WARRANTY
Receiver
24 DigiTrak
®
F2™ Operator’s Manual
2 Point Calibration (In Ground)
The 2PT CAL option allows you to calibrate the receiver to the transmitter when it is in the ground. Two-
point calibration is rarely needed. If you must calibrate with the transmitter in the ground, use this
procedure with caution.
To start the 2-point calibration procedure, select 2PT CAL from the calibration menu. You will see the
following screen.
First Point, 2PT CAL
This screen instructs you to put the receiver on the ground directly above the transmitter, preferably with
the transmitter nearly level. (See the Locating section for instructions on how to position the receiver
directly over the transmitter.)
The flashing trigger symbol at the top of the screen indicates that a trigger click is needed to obtain the
first point for the 2-point calibration. Click the trigger, and the display will count down from 5 to 0 while the
receiver records the first calibration point.
If the signal strength from the transmitter is within the tolerable range (300–950 points), a checkmark will
display on the screen and you will hear the confirmation signal indicating that the first calibration point has
been successfully recorded. Then the second 2PT CAL screen appears.