After selecting the checkmark, the screen will show that the
receiver is calibrating. Do not move the receiver while it is
calibrating.
The second point calibration screen will then appear.
2 Point Calibration, 2nd Point
2. Lift the receiver 3 ft (or 1m) directly up and click the
trigger to initiate calibration of the second point or toggle
right and select the exit option to be returned to the main
menu with no change to the calibration.
3. After selecting the checkmark, the screen will show that
the receiver is calibrating. Do not move the receiver
while it is calibrating. Four short tones and a check mark
on the screen indicate a successful calibration.
After a successful calibration, take a depth measurement at
each calibration point. The difference should be 3 ft ± 2 in. (or
1 m ± 5 cm). Repeat these measurements several times as
you continue drilling to verify that the depth remains valid as
the pitch of the transmitter changes.
Calibration Results
If the calibration is successful, a checkmark will appear on the
screen and you will hear the confirmation signal of four short
beeps. The screen will then return to the main menu with the
locate option highlighted for selection.
If the calibration fails, you will hear two long tones and the