F5 User Guide 26
2 Pt Calibration (Below Ground)
Before Calibration:
A. The receiver must be level and positioned directly above
an approximately level transmitter. See the locating
section for instructions on aligning the receiver directly
above the transmitter.
B. Verify the signal strength at both calibration points (on the
ground and raised 3 ft or 1 m) is between 300 and 950
points. If the signal strength is too high at the first
calibration point, lift the receiver until the signal is within
an acceptable range. The second point for calibration will
then be taken 3 ft (or 1 m) directly above the first point. If
the signal is too low at this point, you will have to pull
back to calibrate.
C. Verify that roll and pitch values are being displayed on
the receiver and that a steady signal is being received
from the transmitter.
To Calibrate:
Select the 2 Pt Calibration option from the calibration menu.
The following screen will display.
2 Point Calibration, 1st Point
1. Click the trigger to obtain the first calibration point or
toggle right and select the exit option to be returned to
the main menu.