User's Manual

DIGITAL CONTROL INCORPORATED
DigiTrak F5 Operator’s Manual 35
Appendix A: System Specifications and
Maintenance Requirements
The power requirements, environmental requirements, and equipment maintenance
requirements for the DigiTrak F5 Locating System are listed below.
Power Requirements
Device (Model Number)
Operational Voltage
Operational Current
DigiTrak F5 Receiver (F5R)
14.4 V (nominal)
350 mA max
DigiTrak F Series Display (FSD)
14.4 V (nominal)
220 mA max
DigiTrak F Series Battery
Charger (FBC)
Input 1028 V
Output 19.2 V
5.0 A max
1.8 A max
DigiTrak F Series Lithium-Ion
Battery Pack (FBP)
14.4 V
4.5 Ah max, 65 Wh
DigiTrak F Series Short-Range
Transmitter (FS)
1.11.6 V
400 mA max
DigiTrak F Series Extended
Long-Range Transmitters (FXL)
23.6 V
750 mA max
DigiTrak HDT and Fluid Pressure
Transmitters (HDT, FPT)
1.77.2 V
650 mA max
DigiTrak DucTrak Transmitters
(DDS 12, DDT 12)
2.43 V
130 mA max
Environmental Requirements
Device
Relative Humidity
Operating Temperature
DigiTrak F5 Receiver
<90%
-4 to 140° F (-20 to 60° C)
DigiTrak F Series Display
<90%
-4 to 140° F (-20 to 60° C)
DigiTrak FS Transmitter
<100%
-4 to 180° F (-20 to 82° C)
DigiTrak HDT and FXL
Transmitters
<100%
-4 to 220° F (-20 to 104° C)
DigiTrak Fluid Pressure
Transmitters
<100%
-4 to 220° F (-20 to 104° C)
DigiTrak DucTrak Transmitters
<100%
22 to 122° F (-5.6 to 50° C)
DigiTrak F Series Battery
Charger
<99% for 3250° F (010° C)
<95% for 5095° F (1035° C)
32 to 95° F (0 to 35° C)
DigiTrak F Series Lithium-Ion
Battery Pack
<99% for < 50° F (10° C)
<95% for 5095° F (1035° C)
<75% for 95140° F (3560° C)
-4 to 140° F (-20 to 60° C)