User's Manual

DIGITAL CONTROL INCORPORATED
xxvi DigiTrak F5 Operator’s Manual
The pressure-tension (P-T) DataLog menu is used with fluid pressure transmitters
and the TensiTrak transmitter. It appears as shown below when the P-T DataLog
function is disabled, which is the default setting. To enable the function, select the
red enable/disable P-T DataLog function icon shown below; the icon will change to
green.
Pressure-Tension DataLog Menu
Note Enabling the P-T DataLog function allows you to record a P-T DataLog
job. The P-T data will display on the Locate Mode screen, however,
whether the function is enabled or disabled.
To start recording, with the function enabled (icon green), select Exit to return to the main
menu, then select Locate Mode to display the following menu.
Pressure-Tension DataLog Start Recording Menu
Select either the option to create a new job or the option to append to an existing job and the
display returns to the Locate Mode screen with data being recorded under the specified job
number. When P-T data is being recorded, the recording icon appears at the lower
right of the transmitter roll indicator. Select Exit from the P-T Start Recording menu and the
Description of highlighted
option
Exit (opens locate
mode screen; no data
recording occurs)
Description of
highlighted option
Delete P-T DataLog
job or jobs
Enable/disable
P-T DataLog function
(green if enabled, red
if disabled)
Exit
Upload P-T DataLog
job to a computer
(shown highlighted)
Append to an
existing job
(opens an existing
job to continue
recording data)
Create a new job
(opens locate mode screen
and begins recording data
under new job number)