User Manual
Table Of Contents
- Operator’s Manual
- Digital
- Control
- Incorporated
- Safety Precautions and Warnings
- Introduction
- System Components
- Startup and Operating Instructions
- SST Operating Procedure
- Setting Up SST Laptop
- Setting Up Equipment and Site
- 2. Establish Borepath Reference Line and Mark Borepath
- 3. Assemble and Torque-up Non-Magnetic Housing to Non-Mag Tool
- 4. Align Drill to Marked Borepath
- 5. Position & Align Non-mag Tooling Assembly onto Marked Borepath
- 6. Stage SST Equipment and Power Sources Adjacent to Tooling Assembly
- 7. Power Up Eclipse SST Equipment
- 8. Measure SST Transmitter Current Draw
- 9. Install SST Transmitter into Aligned Non-mag Tooling Assembly
- Setting Reference Heading (Ref Yaw) and Roll Offset
- Calibrating SST Tool and Confirming Proper System Operation
- Logging Drill Run
- Summary of Basic Operating Procedure
- SST Operating Procedure
- Computer Software Instructions
- Inputting and Changing Drill Data
- APPENDIXImporting Topography, Drill Plan, and Planned Deviation from Excel File
- LIMITED WARRANTY

Operating Instructions
-0.2
%
68
o
F
Yaw Ref: 170.0°
Yaw:169.6°
0.4°
0°
Roll Offset: 240°
SST Remote Screen Showing New Roll Offset Value
End or Change Roll Offset on Remote – You have now set the Roll Offset on the remote display. At the
end of the drill run, or during the run if you want to change the Roll Offset value, you must remove the
Roll Offset value by ending the Roll Offset function. To end the Roll Offset, push the left arrow when at
the steering screen, then select Y for Yes and press the execute button.
12. Set Roll Offset on Receiver
You are now ready to set the Roll Offset function on the receiver. With the receiver already in steering
mode, push the toggle to the right.
iGPS
®
inGround Positioning System
®
DIGITAL
CONTROL
INCORPORATED
®
www.digitrak.com
CH:B1
768.5
-0.2%
90°
61°F
SST Receiver Display for Establishing Roll Offset Value
24 Eclipse
®
SST
®
Operator’s Manual