User's Manual

Table Of Contents
System Setup
64 DigiTrak
®
F5 Operator’s Manual
6. Once the first calibration point is obtained, the second calibration point screen will appear.
2-Point Calibration, Obtain 2
nd
Point
7. Lift the receiver 3 ft (or 1 m) directly up and click the trigger to initiate calibration of the second
calibration point. The calibration-in-progress screen will display again. Do not move the receiver.
8. Once the second point is obtained, the confirmation signal will sound and a checkmark will display on
the screen, indicating a successful calibration. The screen will then return to the locate mode display.
If calibration fails, two long beeps will sound and the failure screen shown below will display. Verify
the setup and try again or call DCI Customer Service.
2-Point Calibration Failure Screen
After successfully completing the 2-point calibration procedure, verify the distance between the two
calibration points by taking depth measurements at each point and then determining the difference
between the two values. The difference should be 3 ft ± 2 in. (or 1 m ± 5 cm). Repeat these measure-
ments several times as you continue drilling to verify that the depth remains valid as the pitch of the
transmitter changes. This is called a two-point check.
(or 1 m)