User's Manual
Table Of Contents
- Safety Precautions and Warnings
- Dear Customer:
- Introduction
- Receiver
- General Description
- Toggle and Trigger Switches
- Audible Tones
- Installing and Removing the Battery Pack
- Power On
- Power Off
- Main Menu
- Locate Mode
- Calibration Menu
- Height-Above-Ground (HAG) Menu
- Settings Menu
- Transmitter Selection Menu
- Drill DataLog Menu
- Pressure-Tension DataLog Menu
- Using the Keypad
- Display Screens
- Standard Receiver Display Screen Symbols
- Transmitter
- Remote Display
- Battery Charger
- System Setup
- Locating
- The Target Steering Function
- Appendix A: System Specifications and Maintenance Requirements
- Appendix B: Projected Depth Versus Actual Depth and the Fore/Aft Offset
- Appendix C: Calculating Depth Based on Distance Between FLP and RLP
- Appendix D: Reference Tables
- LIMITED WARRANTY
System Setup
62 DigiTrak
®
F5™ Operator’s Manual
3. From the receiver main menu, select the calibration menu, and then select the 1-point calibration
option. The following screen will display.
1-Point Calibration Screen
4. Click the trigger to initiate calibration. The screen will show that the receiver is calibrating. Do not
move the receiver.
Calibration-In-Progress Screen
5. When calibration is complete, the confirmation signal will sound and a checkmark will display on the
screen, indicating a successful calibration. The screen will then return to the locate mode display. If
calibration fails, two long beeps will sound and the calibration failure screen will display. Verify the
setup and try again or call DCI Customer Service.
Continue 1-point
calibration
(shown highlighted)
Exit
(returns to
main menu)
10′ (or 3 m)