User's Manual

System Setup
DigiTrak
®
F5 Operator’s Manual 63
If the receiver does not detect a roll signal from the transmitter, the roll offset operation will fail
and the following screen will display.
Roll Offset Failure Screen
Click the trigger to retry setting the roll offset or toggle right to select exit and return to the settings
menu. If the roll offset failure screen appears, verify the setup and try again or contact DCI
Customer Service.
Disable Roll Offset
To turn off the roll offset function, select the disable the roll offset option from the roll offset menu. The
confirmation signal will sound as the screen returns to the settings menu. The value that displays for roll
on the locate mode screens will be that of the transmitter.
Set Height-Above-Ground (HAG) Distance
The height-above-ground (HAG) function allows you to program a height measurement into the receiver
so that you do not have to set the receiver on the ground for a depth reading. Raising the receiver above
the ground provides separation from underground interference, which can reduce the transmitter’s range
or cause variable readings.
1. Before accessing the HAG menu to turn on or set the HAG, you should measure your desired
HAG distance. To do so, hold the receiver comfortably at your side and measure the distance
from the bottom of the receiver to the ground. The available values range from 12–100 in. when
English units are used, or 0.30–2.54 m when metric units are used.
2. From the receiver main menu, select the HAG menu option. You will see the HAG menu with the
enable option highlighted for selection and the current or default (12 in. or 0.30 m) HAG setting
shown in the description line at the bottom of the screen. If the HAG had previously been
enabled, the disable option would show automatically highlighted for selection.