User's Manual

DIGITAL CONTROL INCORPORATED
DigiTrak
®
F5 Operator’s Manual 29
Transmitter
Types of F5 Transmitters
DCI manufactures several different transmitters for use with the F5 system with a total of five frequency
options (1.3 kHz, 8.4 kHz, 12 kHz, 18.5 kHz, 19.2 kHz). All F Series and F5 transmitters provide pitch
readings in 0.1% or 0.1° increments (from 0% to 100% or 0° to 45°). F5 transmitters display roll in 24
clock positions, whereas F Series transmitters display roll in 12 clock positions. This section presents
information for operating the battery-powered F Series and F5 transmitters. For information on operating
the FC cable transmitter, see the DigiTrak Multi-Function Cable Box (MFCB) Operator's Manual.
The transmitter fits inside the drill housing and generates a magnetic field that the F5 receiver can detect.
The F5 receiver must be programmed to detect the specific frequency of the transmitter. Also, the
receiver must be calibrated to the transmitter before drilling and the calibration must be verified.
The transmitter and receiver must have matching regional designation numbers to ensure that they can
communicate and comply with local operating requirements. The transmitter’s regional designation
number is located inside the globe icon (
) near the serial number on long-range and extended long-
range transmitters and on the front end cap of short-range transmitters. This number must match that of
your receiver for proper communication (see Receiver section).
Long-Range F5 Transmitter
The long-range F5 and F Series transmitters all measure 15 in. (38.1 cm) long and 1.25 in. (3.175 cm) in
diameter and have a depth range of approximately 65 ft (19.8 m). Several frequency options are
available, including two dual-frequency transmitters.
The extended long-range transmitters all measure 19 in. (48.26 cm) long and 1.25 in. (3.175 cm) in
diameter and provide a depth range of approximately 85 ft (25.9 m). They are available in 12-kHz (grey)
or 19.2-kHz (black) versions.
Extended Long-Range FXL Transmitter
Transmitter Serial
Number
Regional Designation Number
(Must Match that of Receiver)
Battery Compartment
Front End Cap with
Temp Dot and Index Slot