User`s manual

46
4.4: GENERAL FILTER CONTROL WINDOWS
This section provides detailed description of the control window for each type of processing that the
PCAP II Plus implements in the General Filter, Broadband Filter, and Equalizer processing stages. For
any Filter or Equalizer block, the control window for the selected filter is accessed by clicking on the
Config button.
4.4.1: Ref Canceller Filter
Application:
The Ref Canceller adaptive filter is used to automatically cancel from the Left channel (or
“Primary”) input any audio which matches the Right channel (or “Reference”) input. For
example, the Primary (Left) input is microphone audio with desired voices masked by radio or
TV sound. The radio/TV interference can be cancelled in real-time if the original broadcast
audio, usually available from a second receiver, is simultaneously connected to the Reference
(Right) input.
Figure 4-15 Reference Canceller Filter Control Window