User`s manual

140
entering the desired coefficient number in the text box moves the marker
instantly to the desired point.
Zoom Combo: Used to specify the vertical zoom factor to be used when displaying
coefficients. Coefficients may be zoomed from 1X (no scaling) to a maximum
of 200X. If the scaled coefficient exceeds the maximum vertical display limits,
it will be clipped prior to display. NOTE: This clipping does not affect signal
processing.
Coefficient Display: Coefficients are displayed in Cartesian (X,Y) format, with the Y axis
representing Value in a range from -1.0 to +1.0. The X axis represents Time
in seconds. A yellow grid is superimposed on the black background to assist
the user in visually judging Time and Value of Filter coefficients.
A vertical red marker is used to read out the exact Value and Time of any
Filter coefficient. To move the marker, simply click the mouse cursor on the
desired point in the Coefficient Display area, or utilize the controls in the
Marker Block, described above.
Hide Controls Unchecking this box allows the Coefficient
Checkbox: Display to utilize the full window space;
recheck the box if access to the controls is required.
Print Button: Generate a hardcopy printout of the impulse
response at any time by clicking this button.
Close Button: Clicking on this button or the “X” button at the upper right corner of the
window turns off the Coefficient Display.