User`s manual
108
The Compression Threshold can be adjusted through a range of –90dB to 0dB by using
the scroll buttons beside its text entry box, by entering the value in its text entry box, or by
clicking on the Compression Threshold line using the mouse pointer and adjusting it to
the desired value.
The Compression Ratio can be adjusted through a range of 1:1 to 100:1 by using the
scroll buttons beside its text entry box, by entering the value in its text entry box, or by
clicking on the Compression Ratio Curve using the mouse pointer and adjusting it to the
desired value. NOTE: Only the portion of the ratio to the left of the colon is specified.
The Limit Threshold can be adjusted through a range of –90dB to 0dB by using the
scroll buttons beside its text entry box, by entering the value in its text entry box, or by
clicking on the Limit Threshold line using the mouse pointer and adjusting it to the
desired value.
The Attack Time can be adjusted through a range of 1 to 250 milliseconds by using the
scroll buttons beside its text entry box or by entering the value in its text entry box.
The Release Time can be adjusted through a range of 50 to 2000 milliseconds by using
the scroll buttons beside its text entry box or by entering the value in its text entry box.
Other indicators are the Input and Output Level Displays. The Input Level Display shows
the current envelope level for the stage. The Output Level Display shows the output level
of the stage calculated by multiplying the input envelope by the gain. The current position
on the LCE graph is shown via a “dancing” orange dot. The Current Gain display shows
the current instantaneous gain value of between –90dB and 90dB, as calculated by the
external processor.