Specifications
System Data Structures
ADDvantage-32 PLUS ● AC to DC Power Converter
9-9
The illustrated example for File 28 shows that the Forward Bridge is active and
maximum firing angle has been reached. Additionally, the motor field feedback is within
the 10% setpoint and the drive is configured for the contactor to remain sealed (upon
RUN removal) until ZERO SPEED.
9.3.21 FILE 29 - DDT LABELS
This file contains all predefined label definitions for the digital data table.
One element is used to produce one label. For example:
First element - MAX_A_ALPHA (spaces are shown as __ )
Next element - MIN_A_ALPHA
9.3.22 FILE 30 - DRIVE CAL LABELS
This file contains all predefined label definitions for the drive calibration. One element is
used to produce one label.
For example:
First element - I/O_V-REF
Next element - MOTOR_IARM
9.3.23 FILE 31 -DRIVE CAL UNITS
This file contains the units associated with each of the labels defined in Table 30 for drive
D007
D006
D005
D004
D003
D002
D001
D000
D015
D014
D013
D012
D011
D010
D009
D008
FWD BR ACT
MAX A ALPHA
FLD OK PT
SPD MIN PT
0 0 1 0 0 100
0 0 0 1 1000
LEAST SIGNIFICANT BYTE
MOST SIGNIFICANT BYTE
FIRST ELEMENT =
FILE28LAN