Specifications
IEEE 802.3 Ethernet Communication
ADDvantage-32 PLUS
8-23
DIAGNOSTIC INIT VALUE
5 MIN 10 MIN
IP can't forward
IP fwd same net
IP unknwn proto
IP sent up stack
IP local out
IP pks dropped
IP reassm OK
IP frag'd OK
IP out frg made
IP can't frag
IP bad options
IP no route
IP bad version
IP raw ip's
TCP Connect Init
TCP Connect Esbl
TCP Connect Drpd
TCP 25
TCP 26
TCP 27
TCP 28
TCP 29
TCP 30
TCP 31
TCP 32
ADDvantage-32 PLUS Drive Ethernet Diagnostics Definitions
UDP Mpool Empty: software error counter. Increments if a UDP frame is received and there
is no memory buffer available to hold the frame. This is an internal error. Contact
Engineering if this counter is ever observed to be incrementing.
UDP Mpool Err: software error counter. Increments if the operating system returns an error in
response to a request for a memory buffer. Contact engineering if this counter is ever observed
to be incrementing.