Specifications
Maintenance and Troubleshooting
ADDvantage-32 PLUS ● AC to DC Power Converter
7-7
TABLE 7-2. POWERUP MESSAGES (cont.)
FAULT MESSAGE PROBLEM SOLUTION
-------WARNING-------
INVALID APPLICATION
DEFAULT FAILED
cycle power to reset
Application memory
unable to be
programmed.
a. Replace microprocessor board
-------WARNING-------
NULL APPLICATION
has been loaded
rload valid firmware
Indication message,
result of a load of the
default application.
a. Reload drive firmware and
calibration data.
b. Replace microprocessor board
-------WARNING-------
APPLICATION DOES NOT
MATCH FIRMWARE ID
UP key to continue
Incompatibility detected
between drive hardware
and drive firmware.
a. Insure that correct firmware has
been loaded into drive. This
warning will occur, for example, if
six pulse firmware is loaded into a
12 pulse drive.
b. Replace microprocessor board
-------WARNING-------
CAL/CONFIG DATA
is incompatible with
drive application
Incompatibility detected
between drive firmware
and drive calibration
data.
a. When prompted to default the
cal/config data, press UP key to
allow defaulting. Then reload
calibration data.
b. Insure calibration data is correct
data for this drive
c. Replace microprocessor board
-------WARNING-------
CAL/CONFIG DATA is
corrupt
Invalid calibration and
configuration data
detecting.
a. When prompted to default the
cal/config data, press UP key to
allow defaulting. Then reload
calibration data.
b. Replace microprocessor board.
-------WARNING-------
CAL/CONFIG Checksum
error detected:
ERROR CODE: XX
Drive detected a
checksum error in one
or more sections of the
drive calibration and
configuration data.
a. When prompted to correct the
checksums press the UP key to
allow checksums to be corrected.
Then reload calibration data.
b. Replace microprocessor board
-------WARNING-------
Retentive values
checksum is bad
zeroing out values
Drive detected a
checksum error on one
or more of the retentive
values saved upon
power loss
Pressing any key will acknowledge
this warning. Note that the retentive
values will be zeroed so extreme
caution must be exercised to insure
that the zeroing of the retentive value
will not compromise the safety and/or
operation of the drive application.