Specifications
Maintenance and Troubleshooting
ADDvantage-32 PLUS ● AC to DC Power Converter
7-2
7.1 MAINTENANCE REQUIREMENTS
Proper maintenance of the ADDvantage-32 PLUS and its associated motor and process
equipment is required. Refer to the instructions supplied with the motor and associated
process equipment for proper maintenance procedures.
PERIODIC MAINTENANCE
Under normal operating conditions, the ADDvantage-32 PLUS requires minimal periodic
maintenance. The unit should be checked periodically for dirt accumulation within the
enclosure. Regularly clean or replace filters on low pressure clean air source ventilation
openings. Wire terminations on the power converter should be checked periodically for
tightness.
To minimize downtime in the event of a component failure, spare parts should be stocked
at the installation site. Refer to the spare parts list in the supplemental drawing package
for recommendations on stocking of spare parts.
Use the following checklist for periodic maintenance.
1. Keep unit free from dirt. Vacuum or use low pressure air to keep clean.
2. If cabinet is equipped with filters, keep them free of dirt.
3. Check for correct operation of heat sink fans.
4. Check wire terminations for tightness.
******************************************************
W A R N I N G
THE USE OF UNAUTHORIZED PARTS IN THE REPAIR
OF THIS EQUIPMENT, OR TAMPERING BY
UNQUALIFIED PERSONNEL MAY RESULT IN
DANGEROUS CONSEQUENCES. AVOID LOSS OF LIFE,
SEVERE PERSONAL INJURY OR EQUIPMENT DAMAGE
BY FOLLOWING RECOMMENDED SAFETY AND
REPAIR PROCEDURES.
******************************************************