Specifications

Signal Analyzer
ADDvantage-32 PLUS AC to DC Power Converter
5-4
RECORDER CONFIGURATION DEFAULT
CHANNEL PARAMETER VALUE
______________________________________________________________________
#7 Z***:TRIG7 A/D Q***:ANALOG
Z***:TRIG7 ANALOG A***:ACT SPEED
Z***:TRIG7 DIG D***:FAULT
Z***:TRIG R/F 7 Q***:RISING
Z***:TRIG LEVEL7 0.5
#8 Z***:TRIG8 A/D Q***:ANALOG
Z***:TRIG8 ANALOG A***:ACT SPEED
Z***:TRIG8 DIG D***:FAULT
Z***:TRIG R/F 8 Q***:RISING
Z***:TRIG LEVEL8 0.5
5.3 SAMPLE RATE
The sample rate determines the time span between the recording of each data point. The
rate is determined by specifying the number of 2.777 msec (for 60 Hz systems) time
increments required between samples. For example, the shortest and longest sample
times are:
Sample Time = Z***:RATE X * 2.777 msec
Range of Z***:RATE X = (1 to 99,999)
Shortest Sample Time = (1) * 2.777 msec = 2.777 msec
Longest Sample Time = (99,999) * 2.777msec = 277.7 sec
RECORDER CONFIGURATION DEFAULT RANGE
CHANNEL PARAMETER VALUE
______________________________________________________________________
#1 Z***:RATE 1 18 (50.00 ms). 1-99,999
#2 Z***:RATE 2 18 1-99,999
#3 Z***:RATE 3 18 1-99,999
#4 Z***:RATE 4 18 1-99,999
#5 Z***:RATE 5 18 1-99,999
#6 Z***:RATE 6 18 1-99,999
#7 Z***:RATE 7 18 1-99,999
#8 Z***:RATE 8 18 1-99,999