Specifications
Control Block Description
ADDvantage-32 PLUS
4-105
4.64 SETPOINT
The Setpoint block enables the use of the INC and DEC inputs to modify a setpoint. The
rates for the INC/DEC are adjustable along with the limits. The limits can be defined as
min/max difference or ratio draw. This block is used in the beginning of the speed loop
and tension loop.
FIGURE 4-64. SETPOINT BLOCK
1. Inputs
REF: Analog
RES: Bit
INC: Bit
DEC: Bit
INCR: Analog
DECR: Analog
MAXL: Analog
MINL: Analog
ABS: Bit
UP: Bit
RET: Bit
INC
DEC
MAX
RES
MINL
MAXL
OUT
REF
SETPOINT
REF
OUT