Specifications

Control Block Description
ADDvantage-32 PLUS
4-24
4.17 CDS COUNTS DURING STOP
This block calculates the number of pulses that will be counted during a controlled stop.
It is used in turret applications to determine when the drive run should be removed so that
the turret will stop at the appropriate index position.
FIGURE 4-17. CDS COUNTS DURING STOP BLOCK
1. Inputs
CDS REF: Analog
STOP RT: Analog
CDS ADJ: Analog
GEAR RATIO: Analog
PPR: Analog
2. Outputs
COUNT STOP: Analog