Datasheet
Tag Name
gezeichnet
bearbeitet
geprüft
normgepr.
Maßstab
Tag Name
F/SWB-06
Vervielfält.-Pause
Nr.
Arbeitspause Nr.
Ersatz f.
Zeichn.
Zeichn.-Nr.
951101.4B
Untolerierte Maße Halbzeug, Werkstoff
Ä
nd.
Ä
nd.-Mittlg.
zust. Nr.
28.01.97 Bä
r
29.01.97 Kub
Reliability test
ITEM METHOD OF TEST STANDARD
Storage in high
temp.
Storage in + 80°C test box for 96 hours, then expose to
the room temperature for 2 hours without apllying power.
All specifications must be
satisfied in this condition.
Storage in low
temp.
Storage in – 30°C test box for 96 hours, then expose to the
room temperature for 2 hours without applying power.
All specifications must be
satisfied in this condition.
Life test in the
room temp.
Operate continuously for 1000 hours with applying rated
voltage.
All specifications must be
satisfied in this condition.
Life test in high
temp.
Operate continuously in + 80°C for 500 hours applying 7 V. All specifications must be
satisfied in this condition.
Life test in low
temp.
Operate continuously in – 30°C for 500 hours applying 3 V. All specifications must be
satisfied in this condition.
Temperature
cycle test
Make this test for 5 cycles without applying power, the
expose to the room temperature for 2 hours.
All specifications must be
satisfied in this condition.
Humidity cycle
test
Make this test for 5 cycles without applying power, the
expose to the room temperature for 2 hours.
All specifications must be
satisfied in this condition.
Vibration test
Make this test for the directions of X,Y and Z for 2 hours
each (total 6 hours). To-and-fro sweep times 1 minute.
All specifications must be
satisfied in this condition.
Drop test Drop a buzzer naturally from the height of 700mm to the
surface of 10mm thick woodenboard. Three directions
(x, y & z).
All specifications must be
satisfied in this condition.
Solderability
test
Soldering Temperature: 230°C
Heat applying time: 3 sec.
Page/Blatt 2 von 2