Operating instructions
Performance
Check
and
Adjustment-71380
Control
Settings
Set the
71380
controls
as
follows
:
5-
8
BEFORE
YOU
BEGIN,
see
TRIGGERING
MODE
AUTO
COUPLING
AC
SOURCE
INT
SWEEP
POSITION
TIME/DIV
VARIABLE
MAG
HOLDOFF
Midrange
1
ms
IN
(calibrated)
X1
MIN
B1
.
SET
BASIC
SWEEP
CALIBRATION
a
.
Remove
the
71380
from
the
oscilloscope
mainframe
and
install
the
plug-in
extender
in
the
B
horizontal
com-
partment
.
Then,
install
the
71380
in
the
plug-in
extender
.
b
.
Connect
the
time-mark
generator
to
the
amplifier
unit
input
with
a
50-ohm
cable
.
Set the
time-mark
generator
for
1-millisecond
markers
.
Set
the
mainframe
intensity
and
focus
for
the
desired display
.
c
.
Set
the
LEVEL
control
for
a
stable
display
(TRIG'D
light
on)
.
Set the
amplifier
unit
for
approximately
a
2-
division
display
centered
vertically
on
the
graticule
.
d
.
Set the
front-panel
SWPCAL
adjustment
for
exactly
1
marker/division
over
the
center
8
divisions (position
as
necessary)
.
Performance
Requirement
check
see
introductory
information
.
B
.
HORIZONTAL
SYSTEM
Equipment
Required
1
.
Oscilloscope
mainframe
.
2
.
Amplifier
plug-in unit
.
3
.
Time-mark
generator
.
4
.
Plug-in
extender
.
5
.
50-ohm
cables
(2)
.
6
.
50-ohm
termination
.
TEST
POINT
AND
ADJUSTMENT
LOCATIONS
in
the Diagrams
section
.
~/
B2
.
CHECK
SWEEP
LENGTH
AND
POSITIONING
RANGE
a
.
Horizontally
position
the
display
to
place
the
second
time
marker
to
the
first
graticule
line
.
~/
b
.
CHECK-That
the
end
of
sweep
is
beyond
9
.2
grati-
cule
divisions
(indicates
sweep
length of
at least
10
.2
divisions)
.
c
.
Set the
POSITION
and
FINE
controls
fully
clockwise
.
~/
d
.
CHECK-The
start
of
sweep
must
be
to
the
right
of
graticule
center
.
e
.
Set the
POSITION
and
FINE
controls
fully
counter-
clockwise
.
~/
f
.
CHECK-The
end
of
sweep
must
be
to
the
left
of
graticule
center
.
~/
B3
.
CHECK/ADJUST
MAGNIFIER
GAIN
AND
REGIS-
TRATION
(13430,
13445)
.
a
.
Set the
time-mark
generator
for
0
.1-millisecond
markers
.
b
.
Set the
MAG
switch
to
X10
and
set
the
POSITION
controls to
midrange
.
Set
the
mainframe
intensity
con-
trols
for the
desired display
.
c
.
Check
for
1
marker/division
over
the center
8
divi-
sions
of
display
(position
as