Operating instructions

CALIBRATION
TEST
EQUIPMENT
REPLACEMENT
Calibration
Test
Equipment
Chart
This
chart
compares
TM
500
product
performance
to that of
older
Tektronix
equipment
.
Only
those
characteristics
where
significant
specification
differences
occur,
are
listed
.
In
some
cases
the
new
instrument
may
not
be
a
total
functional
replacement
.
Additional
support
instrumentation
may
be needed
or
a
change
in
calibration
procedure
may
be
necessary
.
wave
available
at
5, 2,
and
1
ns
.
TG
501
-
Marker
outputs,
5
sec
to
1
ns
.
Sine-
wave
available
at
5, 2,
and
1
ns
.
Trigger
output
-
slaved
to
marker
output
from
5
sec
through
100
ns
.
One
time-mark
can
be
generated
at
a
time
.
TG
501
-
Marker
outputs,
5 sec
to
1
ns
.
Sine-
wave
available
at 5, 2,
and
1
ns
.
Trigger
output
-
slaved
to
marker
output
from 5 sec
through
100
ns
.
One
time-mark
can
be
generated
at
a
time
.
REV
.
A,
OCT
1975
184
2901
Comparison
of
Main
Characteristics
-
10
V
output
.
-
Risetime
0
.5
ns
;
30
to
250
ns
Pretrigger
pulse delay
.
-
±10
V
output
.
Short
proof
output
.
-
Paired,
Burst,
Gated,
Delayed
&
Un-
delayed
pulse
mode
;
±10
V
output
.
Short-proof
output
.
Paired
and
Delayed
pulse
;
10
V
output
.
Positive
and
Negative-going
trigger
output
signal,
50 ns
and
1
V
;
High
Amplitude
output,
100
V
.
Comparator
output
can
be
alter-
nately
chopped
to
a
reference
voltage
.
-
Amplitude range
40
mV
to
10
V
p-p
.
-
Frequency
range
350
kHz
to
100
MHz
.
-
Frequency
range
65
MHz
to
500
MHz
.
-
Marker
outputs,
5 sec
to
1
ps
.
Sinewave
available
at
20, 10,
and 2
ns
.
Trigger
pulses
1,
10,
100
Hz
;
1,
10,
and
100
kHz
.
Multiple
time-marks
can
be
generated
simultaneously
.
-
Marker
outputs,
1,
10,
100,
1000,
and
10,000
ps,
plus
10 ns
sinewave
.
184
-
Marker
outputs,
5
sec
to
2
ns
.
Sine-
wave
available
at
50,
20,
10,
5,
and 2
ns
.
Separate
trigger
pulses
of
1
and
.1
sec
;
10,
1,
and
.1
ms
;
10
and
1
ps
.
Marker
amplifier
pro-
vides
positive
or
negative
time
marks
of
25 V min
.
Marker
intervals
of
1
and
.1
sec
;
10,
1,
and
.1
ms
;
10
and
1
/is
.
2901
-
Marker
outputs,
5
sec
to
0
.1
ps
.
Sinewave
available
to
50,
10,
and 5
ns
.
Separate
trigger pulses,
from
5 sec
to
0
.1
ps
.
Multiple
time-marks
can be
gene-
rated
simultaneously
.
NOTE
:
All
TM
500
generator outputs
are
short-proof
.
All
TM
500
plug-in
Instruments
require
TM
500-Series
Power
Module
.
108
PG
502
-
5 V
output
108
111
PG
502
-
Risetime
less
than
1
ns
;
10 ns
111
Pretrigger
pulse
delay
.
114
PG
502
-
t5
V
output
114
115
PG
502
-
Does
not
have
Paired,
Burst,
Gated,
115
Delayed
&
Undelayed
pulse
mode
;
Has
t5
V
output
.
2101
PG
502
-
Does
not
have
Paired
or
Delayed
2101
pulse
.
Has
t5
V
output
.
PG
506
replaces
106
PG
506
-
Positive-going
trigger
output
signal
106
at least
1
V
;
High
Amplitude
out-
put,
60
V
.
067-0502-01
PG
506
-
Does
not
have
chopped
feature
.
0502-01
SG
503
replaces
190,
190A,
190B
SG
503
-
Amplitude
range
5
mV
to
5
.5
V
p-p
.
190B
191
SG
503
-
Frequency
range
250
kHz
to
250
MHz
.
191
067-0532-01
SG
503
-
Frequency
range
250
kHz
to
250
MHz
.
0532-01
TG
501
replaces
180,
180A
TG
501
-
Marker
outputs,
5
sec
to
1
ns
.
180A
Sinewave
available
at
5, 2,
and
1
ns
.
Trigger
output
-
slaved
to
marker
output
from
5 sec
through
100
ns
.
One
time-mark
can be
generated
at
a
time
.
181
TG
501
-
Marker
outputs,
5
sec
to
1
ns
.
Sine-
181
DM
501
replaces
7D13
PG
501
replaces
107
PG
501
-
Risetime
less
than
3
.5
ns
into
107
-
Risetime
less
than
3
.0
ns
into
500
.
50
171
.
108
PG
501
-
5
V
output
pulse
;
3
.5
ns Risetime
.
108
-
10
V
output
pulse
;
1
ns Risetime
.
111
PG
501
-
Risetime
less
than
3
.5
ns
;
8
ns
111
-
Risetime
0
.5
ns
;
30
to
250
ns
Pretrigger
pulse delay
.
Pretrigger
Pulse delay
.
114
PG
501
-
t5
V
output
.
114
-
±10
V
output
.
Short proof
output
.
115
PG
501
-
Does
not
have
Paired,
Burst,
Gated,
115
-
Paired,
Burst,
Gated,
and
Delayed
or
Delayed
pulse
mode
;
t5
V
do
pulse
mode
;
±10
V
output
.
Offset
.
Has
t5
V
output
.
Short-proof
output
.
PG
502
replaces
107