APPENDIX H: SYSTEM TROUBLESHOOTING
APPENDIX H
System Troubleshooting
H.1 Unit does not power up
Consideration should be given to the connection of the equipment to the supply circuit and the eect that overloading of circuits
could have on overcurrent protection and supply wiring.
Questions to ask beforehand (to help nd root cause of issue):
• Was the unit working beforehand? If so, for how long?
• Did anything happen that may have caused this (lightning strike, power failure)?
• Is this unit on a UPS? If so, is it connected on the power-protected side and not the surge side?
H.2 Troubleshooting Questions/Suggestions
CAUTION
This installation should be performed only by a qualied service person; it should conform to all municipal codes.
• Verify that the power lead going into the system is live.
• Check that the power switch is turned on.
• Visually inspect whether the LEDs are on and the power supply and CPU fans are operating.
• Switch the power cord to another outlet.
• Switch to another power cord.
• Open the cover to check voltages with a voltmeter on the power supply. These should be 12v and 5v.
• Inspect the main board for bulging capacitors.
• Check the processor heat sink and make sure it is properly installed.
• Check the diagnostic lights for hardware reference. Boot the system with the Recovery CD in the drive. Go into the Tools area
and then the Diagnostics (Dells Only), then check whether the hard drive detects any problems. If not, try another power
connector.
• DIGIOP™ Technical Support will have to open a trouble ticket with Dell and possibly dispatch an on-site technician in
coordination with the servicing dealer. Or, a replacement part may be sent.
• If all these items have been checked and the problem still cannot be solved in the eld, contact DIGIOP™ Support at
1.877.572.2522.