Specifications

A & E Specifications
DIGIOP ELEMENTS V8.6 DIGIOP, Inc.
Page 12 of 24
Associated resources
2. APG Cash Drawer parameters include:
Name assigned to the data stream
Drawer address and port
Event index (1 .. 6)
Connection type (TCP or Http). For TCP connections, enter the parameter:
Listen Port
For Http connections, enter the parameters:
Address
Port
Username/password
Associated resources
3. Black Analytics (DIGIOP Black cameras) parameters shall include:
Name assigned to the camera, which shall appear under the Data Server in the Object
Tree
IP Address of the camera
Stream number of the camera (Entry is 1)
SSL checkbox (for secure socket layer use)
Username/password/confirm password shall be the security credentials for the
camera’s internal setup
Associated resources (for configuring fraudulent exception transactions) shall bind a
device to an analytic event and shall be used by dragging the analytic device into the
associate resource for the device
4. DigiopNCB, Apollo Access Control Systems, Infinias Intelli-M, pcAmerica, and
RetailJ Register, Micros Register Server, Microsoft RMS, RBH integra32,
Radiant (RFID), Retalix, parameters shall include:
Name assigned to the camera, which shall appear under the Data Server in the Object
Tree
Listen Port shall be the port through with the DVR or NVR receives data from the
device; the IP address of the NVR shall be configured in the sending device
Associated resources (for configuring fraudulent exception transactions) shall bind a
device to an analytic event and shall be used by dragging the analytic device into the
associate resource for the device
5. Gilbarco parameters shall include:
Name assigned the camera, which shall appear under the Data Server in the Object
Tree
TCP or Serial, which camera shall configure an option to receive data through the
selected port
Listen Port (for TCPIP connection) shall be the port through with the DVR or NVR
receives data from the Gilbarco; the IP address of the DVR or NVR shall be configured
in the sending device
Serial Port, Baud Rate, Data Bits, Handshake, Stop Bits, Parity (for serial connection)
shall be settings of the Gilbarco device serial port that is connected to the DVR or NVR
serial port
Associated resources (for configuring fraudulent exception transactions) shall bind a
device to an analytic event and shall be used by dragging the analytic device into the
associate resource for the device
6. Houston Radar Gun parameters shall include:
Name assigned the data stream, which shall appear under the Data Server in the
Object Tree
Serial Port, Baud Rate, Data Bits, Handshake, Stop Bits, Parity (for serial connection)
shall be settings of the Gilbarco device serial port that is connected to the DVR or NVR