Setup guide
6
2. Starting at bay 1 and increasing sequentially, remove a drive tray from the bay for each HDD you are installing. To remove the drive tray, push in the tray lever release button, then use the tray lever to pull
the tray out of the bay.
3. Install an HDD in each drive tray as follows:
NOTE: Use proper ESD procedures when handling HDDs.
a. Position the HDD in the drive tray with the interface connectors toward the back of the tray.
b. Align the screw holes in the sides of the HDD with the back set of holes on the sides of the tray. See the picture below.
HDD interface connectorsTray latch lever
Align holes here
Screw
c. Secure the HDD to the drive tray with 4 screws, 2 on each side.
d. Repeat steps “a”, “b”, and “c” above for each HDD.
4. Reinstall the drive trays in the SV4000 chassis as follows:
a. Slide the drive tray with the HDD numbered Drive 1 into Bay 1 until it is fully in place.
b. Push the tray latch lever in until it clicks and is held in place.
c. Repeat steps “a” and “b” above, installing the HDD numbered Drive 2 into Bay 2, Drive 3 into Bay 3, etc. until all HDD trays are installed.
5. Connect power cables to the both power supply module. Plug them into a UPS (if available) with standard grounded 12 Vac grounded outlets.
NOTE
DO NOT attach the SAS cable to the SV4000 chassis or power on the SV4000 chassis at this time.
C. Installing the STR-CTRL controller card
The STR-CTRL controller card is provided with a full-height faceplate (installed) and a half -height faceplate for use in these chassis:
• Full-height faceplate with card: Use in the 960, 990, 9010, Power Edge R210 chassis and other chassis requiring cards with full-height faceplates.
• Half-height faceplate with card: Use in the XE, 780, 790, 7010 and other chassis requiring cards with half-height faceplates.
Electrostatic Discharge Warning
The DIGIOP® server chassis and the STR-CTRL controller card contain components that can be damaged by electrostatic discharge (ESD). Always follow recommended ESD procedures when handling the
card and other components inside your computers. Use a grounded wrist strap and ESD approved clothing if available. If an ESD wrist strap and ESD protective clothing are not available, touch a bare metal
grounded surface or computer chassis frequently to discharge static from your body.
1. If you are replacing the STR-CTRL controller in a Power Edge R210 , 960, 990 or 9010 chassis, skip this step and continue with step 2. The XE, 780, 790 or 7010 chassis accept only half height expansion
cards. Since the card is provided with a full height faceplate, replace the faceplate with the half height faceplate provided: .
a. Find a at surface in a location that is clean, dust free, and away from high voltage devices such as CRTs and power panels.
NOTE: Use proper ESD procedures when handling the controller board.
b. Remove the controller board from the electrostatic protective packaging and lay it face up on the surface.