User's Manual

Cleaning Instructions
Wipe with a dry cloth
Disposing of your old product
Within the European Union
EU-wide legislaon, as implemented in each Member State, requires that waste electrical and electronic
products carrying the mark (le) must be disposed of separately from normal household waste. This
includes monitors and electrical accessories, such as signal cables or power cords. When you need to
dispose of your display products, please follow the guidance of your local authority, or ask the shop
where you purchased the product, or if applicable, follow any agreements made between yourself.
The mark on electrical and electronic products only applies to the current European Union Member
States.
Guidance and manufacturer’s declaration – electromagnetic immunity
The model CPW-103 is intended for use in the electromagnetic environment specified below. The customer or the user of
the model CPW-103 should assure that it is used in such an environment.
Immunity test IEC 60601
test level
Compliance level Electromagnetic environment
guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
6 kV contact
8 kV air
6 kV contact
8 kV air
Floors should be wood, concrete
or ceramic tile. If floors are
covered with synthetic material,
the relative humidity should be at
least 30 %.
Electrical fast
transient/burst
IEC 61000-4-4
2 kV for power
supply lines
1 kV for input/output
lines
2 kV for power
supply lines
1 kV for input/output
lines
Mains power quality should be
that of a typical commercial or
hospital environment.
Surge
IEC 61000-4-5
1 kV line(s) to line(s)
2 kV line(s) to earth
1 kV line(s) to line(s)
2 kV line(s) to earth
Mains power quality should be
that of a typical commercial or
hospital environment.
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
<5 % UT
(>95 % dip in UT)
for 0,5 cycle
40 % UT
(60 % dip in UT)
for 5 cycles
70 % UT
(30 % dip in UT)
for 25 cycles
<5 % UT
(>95 % dip in UT)
for 5 sec
<5 % UT
(>95 % dip in UT)
for 0,5 cycle
40 % UT
(60 % dip in UT)
for 5 cycles
70 % UT
(30 % dip in UT)
for 25 cycles
<5 % UT
(>95 % dip in UT)
for 5 sec
Mains power quality should be
that of a typical commercial or
hospital environment. If the user
of the model CPW-103 requires
continued operation during power
mains interruptions, it is
recommended that the model
CPW-103 be powered from an
uninterruptible power supply or a
battery.
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
3 A/m
3 A/m
Power frequency magnetic fields
should be at levels characteristic
of a typical location in a typical
commercial or hospital
environment.
NOTE UT is the a.c. mains voltage prior to application of the test level.